ST-600 Series Inline Optical Disinfectant Concentration + Temperature Sensors

Measure the % Concentration of Disinfectants.

Measure for the Real-Time Mass/Mass Concentration of Bleach (Sodium Hypochlorite), Chlorine Dioxide and Acidified NaClO2. Wirelessly monitor, calibrate & configure this sensor via uPyxis® by connecting it to the MA-WB Bluetooth® Adapter.

CE Mark

$3,218.00

- +

Description

The ST-600 Series inline sensors are designed for use in qualitative measurement of real-time mass/mass concentration of a variety of disinfectants to include Chlorine content of concentrated and diluted Sodium Hypochlorite (ST-600 and ST-604), concentration of in-situ Chlorine Dioxide (ClO2) generation solution, low level concentration of Chlorine Dioxide (ClO2) in clean water (ST-605) as well as concentration of Acidified Sodium Chlorite (ASC) in clean water (ST-606), as well as high-range Chlorine concentration in clean water (ST-607) . Unlike typical amperometric sensors for disinfection products the ST-600 Series directly measure the optical density of the solution as either a percentage (% mass/mass) or ppm (mg/L) levels without dilution using a UV light source. The ST-600 Series sensors have a built-in reference light source and a reference light detector in addition to the main light source and main light detector. This configuration ensures a long-term stable measurement of the disinfectant concentration when used in clean (city water quality) carrier water applications. These sensors are factory calibrated using ultra-pure solutions of Sodium Hypochlorite, Chlorine Dioxide and Acidified Sodium Chlorite by Pyxis Lab Inc.

These sensors feature an expanded detection range and an RTD temperature compensated output signal, allowing the user to measure higher temperature compensated concentrations of Sodium Hypochlorite, ClO2 and ASC respectively while obtaining a sample temperature measurement. This feature is highly valuable in compensating for the impact of atmospheric temperature conditions on oxidant solution concentration readings. Pyxis Lab’s unique sensor and optical channel design enables these sensors to be installed in both direct contact and non-contact applications. For high volume chemical streams, the ST-001 inline Tee assembly ¾” NPT is utilized. For low flow chemical applications the clear Teflon Tubing ¼” OD may be used to pass through the sensor optical channel for direct concentration measurement.

Features

  • Break-through Technology measures disinfection liquids from low to high concentrations.

  • Direct-Read technology without dilution or reagent.

  • Long maintenance & calibration cycle – 6 Months Trial.

  • Convenient 3/4” NPT Tee Installation (ST-001) for High Flow Applications.

  • Convenient 1/4” Teflon Tubing Installation for Low Flow Applications.

  • Probe Cleanliness Diagnostics via uPyxis 2.0 app.

  • Expanded Concentration Range

  • Temperature Compensation (RTD) of Oxidant Concentration & Temperature Output Signal.

Specifications

Item ST-600 ST-601 ST-604 ST-605 ST-606 ST-607
Part Number 50231 50231 50233 54148 59433 50670
Target Disinfectant Chlorine Chlorine Dioxide Chlorine ClOâ‚‚ Low Range Acidified NaClOâ‚‚ Chlorine
Target Carrier Measured Industrial Bleach Generator Solution Electrolysis Clean Water Clean Water Clean Water
Unit of Measure % Mass/Mass % Mass/Mass % Mass/Mass ppm ppm ppm
Concentration Output 0.0–16.0% 0.0–0.35% 0.0–2.00% 0.0–100 ppm 0.0–1,200 ppm 0–400 ppm
Lower Detection Limit 0.05% 0.01% 0.01% 0.5 ppm 2.0 ppm 1.0 ppm
Resolution 0.001 in Percentage / 0.1 in ppm
Accuracy Two-Point Calibration against User Created Standard Solutions
Temp. Output Range 4mA 0–32°F; 20mA 100–212°F
Method UV Absorbance
Power Supply 22–26VDC, 2W
Outputs Isolated (2) 4–20mA Analog; RS-485 Modbus
Dimension 6.8in L x 1.44in D
Weight 0.37lbs
Wet Material UPVC; Quartz
Operating Pressure Up to 100psi (6.9Bar)
Temp. Limitations 4–49°C (40–120°F)
Installation Formats 1/4” OD Teflon Tubing through Optical Channel; ST-001 3/4” UPVC Tee
Cables Included 5ft/1.5m Bulkhead IP67; 5ft/1.5m Flying Lead IP67
Rating IP67
Regulation CE / RoHS / UKCA

*NOTE* The ST-600 Series sensors include an optical channel composed of titanium compression installed quartz tubing.
For extreme caustic applications, external Teflon tubing installation is recommended to prevent chemical exposure to the optical channel.

Support Documents

ST-600 Series New User Manual V3.04

ST-600 Series Inline Disinfection Sensors Datasheet

Shopping Cart
Scroll to Top