L-CAL Portable Liquid Formazin Turbidity Calibration Kit

Quick Liquid Calibration Kit for Turbidity.

A portable and reusable liquid-state turbidity calibration kit for rapid calibration of the Pyxis Lab® LT-Series of Ultra-Low Turbidity Sensors.

 

$409.00

Description

The L-CAL Portable Liquid Formazin Turbidity Calibration Kit is a portable and reusable liquid-state turbidity calibration kit. The kit is made to calibrate the LT-Series inline ultra-low turbidity sensors. Furthermore, the LT-Series ultra-low turbidity sensors are factory calibrated using certified Formazin liquid standards. The L-CAL calibration kit allows users to calibrate all LT-Series ultra-low turbidity sensors using smaller volumes of Formazin turbidity calibration standards. This provides an affordable and reusable solution for long term sensor reliability.

In addition, the unique design of the L-CAL liquid calibration kit allows the LT-73X sensor to be easily inserted and calibrated with the sensor in a horizontal position. This allows air bubbles to be evacuated through the integrated air-vent line ensuring superior accuracy of the sensor calibration. The L-CAL has an easy to remove lid allowing users to fill and empty the calibration kit with DI water for vessel/sensor cleaning and Formazin calibration standards for sensor calibration.

Turbidity Calibration Principals & Considerations

The precision, resolution and the low detection limit of the LT-73X Series sensors are not affected by the calibration method.  Regardless of using certified Formazin standards and the L-CAL kit. The calibration only affects the turbidity sensor accuracy. The nature of turbidity measurement makes an absolute turbidity value not easily obtainable for any sensor manufacturer. Proper standards and methods are followed. For example, turbidity values greater than 1.0 NTU measured on real-world samples with different sensors. This could differ significantly depending on the manufacterer. For ultra-low turbidity (less than 0.3 NTU) measurement using the same methods (ISO-7027 or EPA-180.1), it is likely that the values from different sensors can agree within 0.05 NTU. As such, the user should choose a calibration method and remain with the same calibration method for consistency.

Support Documents

L-CAL Liquid Portable Turbidity Calibration Kit Data Sheet

Videos

 

Reviews

There are no reviews yet.

Be the first to review “L-CAL Portable Liquid Formazin Turbidity Calibration Kit”

Your email address will not be published. Required fields are marked *

Shopping Cart
Scroll to Top